Reducing DC Link Voltage Unbalance in a Fault-Tolerant Inverter
2014
Today, continuous working of power inverter drives is mandatory for several applications. Damages to materials, machines or even risks to human life have to be absolutely avoided. In the literature, fault-tolerant algorithms and architectures to achieve a successful fault handling are investigated. Researchers aim at reducing the number and cost of additional components, improving at the same time the inverter performances under postfault conditions. Cost, post-fault power derating and increasing distortion are usually conflicting requirements. In this paper, a fault-tolerant three phase inverter is presented. A reconfigurable architecture and a novel fault-tolerant algorithm is designed to…